Latest Improvements

Atlas

  • Improved rhythm display accuracy on Atlas Junior and Baby by ignoring slight compressions (≤10 mm Junior, ≤6 mm Baby)
  • Resolved PSIMV mode issues: PSync now saves correctly, pInsp changes send properly, and switching PSync updates all controls
  • Added ventilator settings to Scenario Events: parameters can be viewed, edited, and synced directly from event cards

Camera

  • Enhanced NIBP display and logging: values now appear in exported videos, redundant logs removed, and event labels simplified

Corpuls

  • Improved pacing display: C3 shows correct pacing lozenge; C1 applies continuous therapy with visible ‘STIM’ label
  • Fixed Scenario Review Timeline for accurate playback
  • Updated German translations: “Cancel” → “Abbr.”, “Demand” in uppercase, “Schrittmacher” → “Schrittm”

CPR Band

  • Added Bluetooth signal strength (RSSI) logging to detect interference
  • Logs now show “OK” or “Warning” based on signal stability

Hamilton T1

  • Aligned Facilitator settings with Hamilton T1 parameters for consistent operation
  • Adjusted ranges, increments, and validations for all key controls
  • Improved spontaneous rate and I:E ratio interaction for stable timing
  • Standby timer now starts only after a ventilation cycle
  • Alarm settings retain correct values when switching modes or patient types
  • Neonatal alarms reset to defaults and display valid limits
  • Resolved overlapping Pressure Alarm dials to maintain proper top/bottom order
  • Improved Trends tab and submenu behavior for smoother navigation
  • Menus now close automatically when entering Standby
  • Fixed I:E ratio display in SIMV+ and PSIMV+ modes
  • Ventilation and ExpMinVol values display correctly with one decimal and retain settings after weight or alarm changes
  • Adjusted PEEP/CPAP dial so max indicator appears only within valid range
  • Patient type switching now resets values correctly; “Last Patient” retains defaults
  • Resolved alarm dial overlaps for proper display order

Nihon Kohden – EMS1052

  • Fixed CPR elapsed time reset and “Restart CPR” timing (now 10 s)
  • Improved Japanese Cardioversion messages with corrected layout and font
  • Added suspend time messages: “Suspend 10s,” “20s,” and “Restart CPR 30s” appear during pauses and clear on resume

Scenarios

  • Added 100+ training scenarios: 73 Adult, 17 Paediatric, 13 Neonatal
  • Organized under new folder structure; existing scenarios unchanged

Multiple Hardware

  • Fixed “No connected device” message display after disconnecting all devices
  • Added automatic Bluetooth reconnection after unintended disconnects
  • Manual disconnects remain user-controlled
  • Renamed devices retain connections with consistent log updates

Multiple Screens

  • Fixed behavior when electrodes or pads are disconnected
  • Heartbeat sounds and rate alarms now stay inactive until proper connection

Visit the App Store today to update your REALITi 360 system