Boost Performance with REALITi 360 11.21.0 Update

REALITi Version 11.21.0
Latest Improvements
Atlas
- Improved Pleth (SpO₂ waveform) behavior during CPR so pulses remain visible during compressions and can reflect both intrinsic cardiac activity and CPR-generated pulses
- Introduced a dedicated Pulse Rate (PR) value separate from Heart Rate (HR), improving handling of pulseless states, CPR, low perfusion, and probe disconnection while keeping PR aligned with HR by default
Camera
- Exported videos now include ECG, SpO₂, and ETCO₂ waveforms as shown in live preview
Corpuls
- Improved AED analysis: removed incorrect “Patient Movement Detected” message and enhanced shock decision timing using ECG analysis blocks
- Added CPR depth support with manikin-specific ranges
- Improved CO₂ and apnea alarm behavior, including correct triggering and translations
- Added SpO₂ probe-off alarm with localized messaging
- Fixed metronome audio and defibrillator behavior, including QRS marker display and power-on logic
- Ensured alarm notifications clear correctly after Autolimits adjustments
CPR Band / CPR Puck
- Improved Bluetooth connectivity and compatibility with newer devices
CPR Console
- Fixed compression depth unit conversion and display accuracy
Facilitator/Control
- Improved ECG waveform behavior: heart rate now correctly updates or persists depending on waveform type
- Corrected passive rate values on select ECG waveforms and fixed a waveform naming typo
- Added configurable sound settings (volume, alarm, heartbeat) within events, including scenario saving, defaults, and clear display states
- Improved auscultation menu behavior to prevent overlap and ensure proper closing during navigation
- Fixed layout issues with tab labels in languages with longer text
- Added collapsible folders in the Scenario Library
- Improved connection handling between Control and Monitor, including reconnection after Wi-Fi loss
- Resolved connection stability issues to prevent repeated reconnection attempts while awaiting monitor selection, eliminating device flickering
- Corrected unintended event behaviour so sound-related settings (e.g., Alarm Off) only appear when explicitly configured
LIFEPAK 35
- Corrected ETCO₂ sweep speed and waveform display to better match real device behavior
Menu/Main Screen
- Fixed the issue where the Settings page could appear blank on some iOS devices
Revel Vent
- Fixed crash when connecting Control to the monitor
SimConnect
- Updated firmware (v1.4.0) with improved logging and behaviour consistency
- Improved Wi-Fi settings retrieval during SimConnect connection, including clearer loading prompts and retrying settings requests if the router is still starting up
SimOccluder
- Updated firmware (v1.2.0) for improved performance, reliability, and stability
- Updated in-app branding
Zoll R
- Added configuration options for AED startup mode and automatic AED analysis
Zoll X
- Fixed 12-lead ECG display reverting incorrectly in Torsades rhythm
- Added CPR metronome audio feedback
- Updated ETCO₂ monitoring to include automatic calibration on activation
Multiple Screens
- Fixed missing exit prompt on monitor screens
- Prevented automatic BP from starting while the monitor is off
Maintenance and General
- Updated compatibility with the latest Apple system updates
- Standardized screen orientation (landscape by default; portrait where required)
- Fixed unit consistency in exported videos (ETCO₂ and temperature)