Atlas

  • Added support for Atlas Adult Next Gen
  • Implemented Atlas Baby bootloader firmware update. It will only update if there is a new firmware MCU app update

Corpuls

  • Corrected texts to “corpuls simulation”
  • Corrected "VT/VF possible" translation in DE for C3
  • Improved metronome automatic start settings for manual defibrillator and AED, to display correct metronome setting when switching between AED and manual defibrillator
  • Set the on-state default value to Adult 30:2 for the automatic start of the metronome in both manual and AED settings

CPR Band

  • Updated CPR recommendation statement for CPR device renaming
  • Updated renaming rule to accept only the new naming format
  • Updated CPR recommendation statement for CPR device renaming - CPR sensor name should contain CPR-

Facilitator/Control

  • Added a randomiser for the Arterial line to be in effect when the line is inserted while RR value is zero
  • Resolved crashing when ‘HOLD TO SPEAK’ is tapped while recording
  • Added a message in the User Recordings window to indicate when no recordings are saved
  • Disabled the 'HOLD TO SPEAK' button during recording or until the recording is saved or discarded
  • Added ‘HOLD TO SPEAK’ button in dark mode
  • Updated UI for ‘New Recording’ menu when recording
  • Added prevention on selecting other Sound categories while recording
  • Changed how User Recordings and New Recording appear; selecting User Recordings now will show both together

Hamilton T1

  • Resolved the issue of Neonate weight dial minimum value lowering the minimum value of Vt past the limit
  • Set up the default value for parameter Rate to depend on IBW (adult) or weight (neonatal) values
  • Adjusted Neo SPONT mode limits to Basic, More, and Apnea options
  • Improved Neo SPONT mode values
  • Resolved the issue of the Standby Screen becoming unresponsive after pressing the Power button while a parameter dial is active (orange)
  • Activated Tools window button
  • Initialized Tools window
  • Added initial Utilities and Configuration tabs including contents
  • Updated Neonatal UI options in Standby mode
  • Added the three Neonatal quick setup buttons
  • Created the Neonatal dial with a default of 2.0kg and allows weight adjustment
  • Improved last Patient tab UI with the ability to recall the last patient data
  • Corrected the default Last Patient tab on the first load of Standby
  • Initialized Events window

Nihon Kohden — EMS1052

  • Created a simulated CPR waveform
  • Added CPR waveform in AED, Manual, and Monitor modes (comp bars excluded)
  • Added CPR elapsed time including how it resets when a new CPR device connection is established
  • Resolved Pad messages appearing behind the CPR guide-lines
  • Updated the JA text display ‘Do 5 more chest compressions. Do not touch 'patient' in AED by removing an unnecessary symbol
  • Resolved the issue of multiple texts appearing on Press Scale options while in the JA language
  • Resolved the issue of the ‘Use Disposable Pads’ voice overlap with the ‘Press AED button’
  • Added restriction to the use of the charge button when Pads are off
  • Resolved the issue of “CPR Assist” message appearing in Pacing even when there is no CPR assist connected
  • Corrected the EN text display ‘Do 5 more chest compressions. Do not touch 'patient' in AED by removing an unnecessary symbol
  • Resolved the issue of waveforms (EtCO2, SpO2) resetting after Send is pressed from Control
  • Initialized behavior for the Alarm slider’s up and down arrows when it reaches the limit by changing it to a light grey color when they become ‘disabled’ or ‘off’

Zoll

  • Resolved where Zoll monitors were experiencing crashes after switching from a different monitor with VT/VF alarms occurring before or after the switch
  • Added 8-sec timer in Zoll X monitors to close defibrillator window and return to the home screen after a shock is delivered

Multiple Screens

  • Resolved parameter values for vitals: HR, SpO2, ETCO2, etc. not updating correctly

Translation Improvements

  • Updated Brazilian Portuguese translations
  • Added adjustments to Zoll X, LifePak 15, and CPR Console to ensure Brazilian Portuguese translations fit appropriately
  • Updated Simplified Chinese REALITi Translation